透气钢冷却管的安装方法(如果必要)

在porcerax II透气钢使用dichtol密封胶前,有一点至关重要,必须将EDM液体或者其他切削油是从钢毛孔彻底清除。如果不这样做,将大大增加由于水泄漏是由于dichtol密封胶无法渗入毛孔或者使密封胶脱落,引起的泄露会使污染物占据porcerax II透气钢的气孔。

密封水管线前的清洗程序:

Porcerax II
Sealing Water Lines in Porcerax II with Dichtol
Before applying Dichtol to waterlines in Porcerax, it is imperative that all EDM fluids and other cutting oils be completely removed from the pores of the steel. Failure to do so greatly increases the risk of water leaks due to the inability of the Dichtol to leach into the pores; the contaminants will occupy the pores of the steel or will prohibit the Dichtol from bonding to the surfaces.
Cleaning Procedures Before Sealing Water Lines:
Step 1.
Heat the block of Porcerax II to 300°F for at least (1) one hour. This will open the pores and thin the fluids, allowing most of the trapped material to wick from the steel.
Step 2.
After cooling to room temperature, soak the Porcerax II insert in an ultrasonic cleaner (built for flammable solvents) filled with acetone. These units have spark-proof switches, water chillers and are temperature monitored. This is the only recommended type cleaner for cleaning Porcerax II.
Clean for approximately 1 to 4 hours, depending on insert size, back flushing with filtered shop air and changing the acetone after every hour. When the acetone remains clear the insert should be clean.
Step 3.
Dry with filtered shop air, and let stand overnight.
Note: In addition to the other cleaning methods, it may be necessary to back-flush the Porcerax II inserts with acetone, using air pressure, in order to thoroughly clean the inserts. Care should be taken when using solvents under pressure.
Note: Any hot substance introduced to acetone will cause a flash fire! Make absolutely sure the Porcerax II block is at room temperature!
Applying the two types of Dichtol sealant to Porcerax II waterlines.
Step 4.
Cover all water line inlets but one with a suitable tape. After tape has been applied, stand piece on edge and fill water line through the one remaining open line with Dichtol "WFT" for the 7 micron size. Use Dichtol Macro for 20 micron size. Apply tape over the one remaining water line inlet.
Step 5.
Slowly rotate the piece in all directions to insure the Dichtol is evenly distributed throughout the water line circuit. Let stand for 15-20 minutes.
Step 6.
Remove the piece of tape from the water line where Dichtol "WFT" was first poured into the insert. Pour the Dichtol from the insert back into the container for reuse.
Step 7.
Let stand empty 2 hours.
Step 8.
Re-tape the original hole, and uncover a hole on the opposite side of the insert.
Step 9.
Pour in Dichtol "Macro" for all micron sizes.
Step 10.
Repeat steps 5 & 6.
Step 11.
Allow 24 hours drying time before applying water pressure to the piece.
Note: Dichtol that has cured can only be removed with Methylene Chloride, Acetone or Dichtol Remover.
Note: Dichtol can be obtained from Devitt Machinery, Aston, PA. Tel: (610)494-2900.
Diamant Metallplastic is the worldwide operating manufacturer of Dichtol for the impregnation of micropores. For more information on Dichtol, visit their website: